Multi-loose Tube Amored Fiber Resistant Cable

Operating wavelengthMode Field DiameterCladding DiameterCoating Diameter

Product Details

Fiber Parameters

No.

Items

Unit

Specification

SM

1

Operating wavelength

nm

1310

nm

1550

nm

1625

2

Mode Field Diameter

1310nm

μm

(8.6~8.8)±0.4

1550nm

μm

9.8±0.5

3

Cladding Diameter

μm

125±0.7

4

Coating Diameter

μm

245±7

5

Max attenuation Tight buffer

1310nm

dB/km

≤0.4

1550nm

dB/km

≤0.3

6

Max attenuation Loose tube

1310nm

dB/km

≤0.37

1550nm

dB/km

≤0.22

1625nm

dB/km

≤0.25


No.

Items

unit

Specification

OM1

OM2

OM3

OM4

1

Operating wavelength

nm

850

nm

1300

2

Core Diameter

μm

62.5±2.5

50±2.5

50±2.5

50±2.5

3

Cladding Diameter

μm

125±2

125±1

125±1

125±1

4

Coating Diameter

μm

245±10

242±7

242±7

242±7

5

Max attenuation Tight buffer

850nm

dB/km

3.5

3.5

3.5

3.5

1300nm

dB/km

1.5

1.2

1.2

1.2

6

Max attenuation Loose tube

850nm

dB/km

3.2

2.8

2.8

2.8

1300nm

dB/km

1.0

0.9

0.9

0.9


Cable Parameters

Items

Specifications

Fiber Count

6

Colored Coating Fiber

Dimension

250µm±15µm

Color

Blue、Orange

Loose Tube

Dimension

2.4mm±0.1mm

Material

PBT

Color

Red、Green、Natural

Fireproof tape

Size

0.2*9mm

Material

Micatape

Filler

Dimension

3.0mm±0.1mm

Material

PP

Color

Natural

Central Strength Member

Diameter

0.8mm

Material

Steel

Cushion

Diameter

1.5±0.1mm

Material

SHF1/SHF2/SHF2

Tape

Material

Nonwoven Fabric

Size

0.2*25mm

Inner Jacket

Dimension

9.3mm±0.2mm

Material

SHF1/SHF2/SHF2

Color

Black

MetallicArmor

Material

Galvanized Steel Wire

Diameter of wire

0.2mm

Coverage

85% Min.85%

Outer Jacket

Dimension

13.2mm±0.5mm

Material

SHF1/SHF2/SHF2

Color

Black


Mechanical and Environmental Characteristics

Items

Unite

Specifications

Tension(Long Term)

N

600

Tension(Short Term)

N

1500

Crush(Long Term)

N/10cm

300

Crush(Short Term)

N/10cm

1000

Min. Bend Radius(Dynamic)

mm

25D

Min. Bend Radius(Static)

mm

12.5D

Installation Temperature

-10~+60

Operating Temperature

-40~+70

Storage Temperature

-40~+70


1. Fiber cable mechanical performance

1) Tensile Strength

Test Method: IEC 60794-1-2 E1

Test Length: ≥50m

Test Condition: Loading 1500 N, continue 1 hour

Acceptance criterion: Single-Mode change less than 0.2dB; Multi-mode change less than 0.3dB


2) Squash

Test Method: IEC 60794-1-2 E3

Test Condition: 1100 N/ 10cm,Continue 10 minutes、1 point

Acceptance Criteria: Single-mode change less than 0.2dB; Multi-mode change less than 0.3dB; No sheath broken and no fiber cracked


3) Impact

Test Method: IEC 60794-1-2 E4

Test Condition: impact energy1J,Cylindrical surface radius 12.5mm,Three point each time

Acceptance criteria: Single-Mode change less than 0.2dB; Multi-mode change less than 0.3dB; No sheath broken and no fiber cracked


4) Repeated bending

Test Method: IEC 60794-1-2 E11A

Test Condition: Mandrel diameter 20D 、Cycle times 10 times

Acceptance criteria: Single-mode change less than 0.2dB; Multi-mode change less than 0.3dB; No sheath broken and no fiber cracked


5) Winding

Test Method: IEC 60794-1-2 E7

Test Condition: Cable Length 2m、Twisting times 10 times、Twisting angle ±180℃

Acceptance Criteria: Single-mode change less than 0.2dB; Multi-Mode change less than 0.3dB; No sheath broken and no fiber cracked


2. Fiber environment performance

1) Temperature attenuation characteristics

Test Method: IEC 60794-1-2 F1

Test Condition: Cable Length 1000m、Temperature cycle23℃-40C 70C、keep warm time 24h、 Cycle times 2 times

Acceptance Criteria: Single-mode change less than 0.2dB; Multi-mode change less than 0.3dB


2) Combustion performance

Fire resistance: IEC 60331-25

Flame retardant: IEC 60331-25

Flame resistance: IEC 60332-3-22

Halogen content: IEC 60754-1

Smoke density: IEC 61034-2


3. Fiber cable identification

Outer sheath marked with white identification, the interval is 1m,Identification is as follows, Other information can provide according to customer requirements

1) Fiber cable type and fiber core number

2) Name of manufacture

3) Year of manufacture

4) Length Identification


Inquiry

Related Products