No. | Items | Unit | Specification | |
SM | ||||
1 | Operating wavelength | nm | 1310 | |
nm | 1550 | |||
nm | 1625 | |||
2 | Mode Field Diameter | 1310nm | μm | (8.6~8.8)±0.4 |
1550nm | μm | 9.8±0.5 | ||
3 | Cladding Diameter | μm | 125±0.7 | |
4 | Coating Diameter | μm | 245±7 | |
5 | Max attenuation Tight buffer | 1310nm | dB/km | ≤0.4 |
1550nm | dB/km | ≤0.3 | ||
6 | Max attenuation Loose tube | 1310nm | dB/km | ≤0.37 |
1550nm | dB/km | ≤0.22 | ||
1625nm | dB/km | ≤0.25 |
No. | Items | unit | Specification | ||||
OM1 | OM2 | OM3 | OM4 | ||||
1 | Operating wavelength | nm | 850 | ||||
nm | 1300 | ||||||
2 | Core Diameter | μm | 62.5±2.5 | 50±2.5 | 50±2.5 | 50±2.5 | |
3 | Cladding Diameter | μm | 125±2 | 125±1 | 125±1 | 125±1 | |
4 | Coating Diameter | μm | 245±10 | 242±7 | 242±7 | 242±7 | |
5 | Max attenuation Tight buffer | 850nm | dB/km | 3.5 | 3.5 | 3.5 | 3.5 |
1300nm | dB/km | 1.5 | 1.2 | 1.2 | 1.2 | ||
6 | Max attenuation Loose tube | 850nm | dB/km | 3.2 | 2.8 | 2.8 | 2.8 |
1300nm | dB/km | 1.0 | 0.9 | 0.9 | 0.9 |
Cable Parameters
Items | Specifications | |
Fiber Count | 8 | |
Colored Coating Fiber | Dimension | 250µm±15µm |
Color | Blue、Orange、Green、Brown、 Gray、Whtie、Red、Black | |
Loose Tube | Dimension | 3.5mm±0.1mm |
Material | PBT | |
Color | Green | |
Micatape | Size | 0.13*20mm |
Strength Member | Glass Yarn | |
Ripcord | Number | 2 |
Color | Red | |
Outer Jacket | Dimension | 10.5mm±0.3mm |
Material | SHF1/SHF2/SHF2 | |
Color | Orange |
Mechanical and Environmental Characteristics
Items | Unite | Specifications |
Tension(Long Term) | N | 1000 |
Tension(Short Term) | N | 3000 |
Crush(Long Term) | N/10cm | 300 |
Crush(Short Term) | N/10cm | 1000 |
Min. Bend Radius(Dynamic) | mm | 20D |
Min. Bend Radius(Static) | mm | 10D |
Installation Temperature | ℃ | -20~+60 |
Operating Temperature | ℃ | -40~+70 |
Storage Temperature | ℃ | -40~+70 |
1. Fiber cable mechanical performance
1) Tensile Strength
Test Method: IEC 60794-1-2 E1
Test Length: ≥50m
Test Condition: Loading 1500 N, continue 1 hour
Acceptance criterion: Single-Mode change less than 0.2dB; Multi-mode change less than 0.3dB
2) Squash
Test Method: IEC 60794-1-2 E3
Test Condition: 1100 N/ 10cm, Continue 10 minutes、1 point
Acceptance Criteria: Single-mode change less than 0.2dB; Multi-mode change less than 0.3dB; No sheath broken and no fiber cracked
3) Impact
Test Method: IEC 60794-1-2 E4
Test Condition: Impact energy1J, Cylindrical surface radius 12.5mm,Three point each time
Acceptance criteria: Single-Mode change less than 0.2dB; Multi-mode change less than 0.3dB; No sheath broken and no fiber cracked
4) Repeated bending
Test Method: IEC 60794-1-2 E11A
Test Condition: Mandrel diameter 20D、Cycle times 10 times
Acceptance criteria: Single-mode change less than 0.2dB; Multi-mode change less than 0.3dB; No sheath broken and no fiber cracked
5) Winding
Test Method: IEC 60794-1-2E7
Test Condition: Cable Length 2m、Twisting times 10 times、Twisting angle ±180℃
Acceptance Criteria: Single-mode change less than 0.2dB
0.3 dB Multi-Mode change less than 0.3dB
No sheath broken and no fiber cracked
2. Fiber environment performance
1) Temperature attenuation characteristics
Test Method: IEC 60794-1-2 F1
Test Condition: Cable Length 1000m、Temperature cycle23℃-40C 70C、keep warm time 24h、Cycle times 2 times
Acceptance Criteria: Single-mode change less than 0.2dB; Multi-mode change less than 0.3dB
2) Combustion performance
Fire resistance: IEC 60331-25
Flame retardant: IEC 60331-25
Flame resistance: IEC 60332-3-22
Halogen content: IEC 60754-1
Smoke density: IEC 61034-2
3. Fiber cable identification
Outer sheath marked with black identification, the interval is 1m,Identification is as follows, Other information can provide according to customer requirements
1) Fiber cable type and fiber core number
2) Name of manufacture
3) Year of manufacture
4) Length Identification
Inquiry